Technical Paper
Investigation of a Novel Aid for Cold Starting of Diesels
1989-02-01
890041
An experimental investigation of the use of an engine coolant exchange system for prewarming diesel engines before cold starting is discussed. This coolant exchange system involves connecting the coolant system of a fully warmed-up and running engine (e.g., a spark ignition engine) to that of the cold diesel to be started using hydraulic hoses with quick connect fittings and an auxiliary pump. The investigation was performed using a 4,3 liter V6 indirect injection diesel engine since this represents a difficult case for cold starting. The starting characteristics using the coolant exchange technique are compared to those using the production glow plug system, which includes a fuel heater and afterglow. It is shown that the coolant exchange system allows this engine to be started down to −26 °C, much colder than the −13°C limit for the production glow plug system.